5 Servicing

The recommended service procedures identified in table 5.2 and all other repair and calibration work should be undertaken by a Parker
domnick hunter trained, qualified and approved engineer.

5.1 Cleaning

Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may use a mild
detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.

5.2 Service Intervals

Description Of Maintenance Required
Component
Dryer
Check POWER ON indicator is illuminated.
Dryer
Check STATUS / FAULT indicators located on the controller.
Dryer
Check for air leaks.
Dryer
Check the condition of electrical supply cables and conduits.
Dryer
Check for cyclic operation.
Filtration
Check Drain operation
Replace active exhaust silencers
Dryer
Recommended Service A
Replacethe inlet and outlet air filters and service drains
Filtration
Recommended Service B
Service valves
Dryer
Recommended Service D
Replace the Desiccant.
Dryer
Recommended Service E
Key:
- Check
Note: When cartridges require changing an audible alarm will sound every 6 seconds.
Temporary resetting of the alarm to prevent nuisance noise is possible after alarm has sounded for the first time. This is done by depressing
once the reset button located inside the control enclosure, accessed by removing the black insert on the side. The alarm will be muted for a 24
hour interval until the dryer has been serviced and the reset sequence completed.
Operation
– Replace
Typical Recommended Maintenance Interval