Window-Based Protocol - Varian Turbo-V 700 ICE Manual De Instrucciones

Tabla de contenido

Publicidad

Window-Based Protocol

The following table, valid for the RS 232, RS 422 and RS 485 interfaces, describes each single window used in the
protocol.
WIN
R W T
000
X X L START/STOP
001
X X L SPEED SELECTION ACTIVE [0=HS / 1=LS]
100
X X L SOFT START [0=NO / 1=YES]
102
X X L WATER COOLING [0=NO / 1=YES]
107
X X N MODE (0, 1, 2) [FRONT, REMOTE, SERIAL]
108
X X N BAUD_RATE (0-4) [600, 1200, 2400, 4800, 9600]
109
X L PUMP LIFE RESET AND FLOW METER ALARMS (TYPE "ON" TO RESET)
110
X X N THRESHOLD HS [Krpm]
111
X X N THRESHOLD LS [Krpm]
112
X X L HEATER JACKET ENABLE [0=ON / 1=OFF]
113
X X N HEATER JACKET TEMPERATURE SETTING [Degrees]
114
X X L GAS TYPE [0=N
115
X X N THRESHOLD FLUSSIMETRO [sccm]
116
X X N HIGH SPEED ADJUST [Krpm]
117
X X N LOW SPEED ADJUST [Krpm]
118
X X L LOWER BEARING TEMPERATURE MEASUREMENT ENABLE [0=NO / 1=YES]
119
X X L HOST / PRINTER MODE [0=HOST / 1=PRINTER]
200
X
N CURRENT [A]
201
X
N VOLTAGE [V]
202
X
N POWER [W]
203
X
N FREQUENCY [Krpm]
205
X
N PUMP STATE (0÷6) [STOP, WAITING INTERLOCK, STARTING, NORMAL,. HIGH LOAD,
FAILURE, APPROACHING]
206
X
N ERROR CODE (0÷7) [NO ERROR, OVERVOLTAGE, SHORT CIRCUIT,CHECK CONNECTION,
TOO HIGH LOAD, OVERRIDE, PUMP OVERTEMP, CONTROLLER OVERTEMP]
207
X
L STATE S1 [0=OFF / 1=ON]
208
X
L STATE S2 [0=OFF / 1=ON]
209
X
N UPPER BEARING TEMPERATURE [0-99 °C]
210
X
N LOWER BEARING TEMPERATURE [0-99 °C]
211
X
N FLOW READ [0-100 sccm]
212
X
L STATUS OUTPUT FLOW METER [0=OFF / 1=ON]
213
X
N FLOW METER ALARM TIME RELATING TO THE LAST EVENT
214
X
N FLOW METER ALARM CYCLE NUMBER RELATING TO THE LAST EVENT
215
X
N FLOW METER ALARM EVENT NUMBER
300
X
N CYCLE TIME
301
X
N CYCLE NUMBER
302
X
N PUMP LIFE
400
X
A CRC PROGRAM LISTING
402
X
A CRC PARAMETER LISTING
WIN = Window
R
= Read
W
= Write
/ 1=Ar]
2
(0-999.999) IN MINUTES
(0- 65.535) IN COUNTS
(0-999.999) IN HOURS
T = Type:
L = Logical
N = Numeric
A = Alphanumeric