4.1- Learning mode:
- Switch the motor ON.
- Simultaneously press the "UP" and "DOWN" keys of a Hz transmitter.
The motor will run for 0,5 second in one direction, then in the other. The
transmitter now controls the motor in unstable mode, move to stage 4.2.
4.2- Checking the rotation direction:
Press the "UP" key of the transmitter:
a- If the motorized tube runs in the UP direction, move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the "Stop" key for at least 3 seconds. The
motor will confirm the reversal of the rotation direction by running for 0,5 second in one direction, then in the other direction. Move to the
stage 4.3.
4.3- Adjustement of the end-limits : memorizing the end points:
The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position (a) and then the UP position (b).
- First you can memorize the UP position (b) and then the DOWN position (a).
a
1- Position the motor on the DOWN end limit using the
"DOWN" and "UP" keys.
2- To memorize the DOWN end limit position, press
simultaneously the "STOP" and "UP" keys. The motor
will run automatically in the UP direction.
3- Before the motor reaches the UP end limit, press the
"STOP" key.
4- After the adjustment of the DOWN (a) and the UP (b) end limits, confirm the settings:
- Press 2s on the "STOP" key to validate the settings. The motor will stop and will run
for 0,5 second in one direction and then in the other. Go to next step.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
5
Programming the first individual point of control
This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter PROG Key for approximately 1 second. The
motor will run for 0,5 second in one direction and then in the other.
Your transmitter is now programmed to control the motor in stable
mode.
EN
3/5
b
1- Position the motor on the UP end limit using the "UP"
and "DOWN" keys.
2- To memorize the UP end limit position, press
simultaneously the "STOP" and "DOWN" keys. The
motor will run automatically in the DOWN direction.
3- Before the motor reaches the DOWN end limit, press
the "STOP" key.