5 Commissioning
5.1 Teach-in of the device
In order be integrated into the Alpha IP System and to communicate with other
devices, the room control unit Analog must be taught-in first. The room control unit
Analog is taught-in directly to the Alpha IP base station, or in conjunction with the
radiator thermostats, to the Alpha IP Access Point. In case of direct teach-in, the
configuration is done on the device itself; in case of teach-in via the Access Point, it
is done via the Alpha IP app.
5.1.1 Teach-in to Alpha IP Base Station
For teach-in, keep a minimum distance of 50 cm between the devices.
The teach-in process can be interrupted by shortly pressing the teach-in key
again. This is confirmed by a short flash in red colour of the device LED.
If no teach-in is performed, the teach-in mode is finished automatically
after 30 seconds.
If the room control unit Analog shall be taught-in to the Alpha IP Base station, the
two devices to be linked must be set to teach-in mode.
Commissioning
31