USING THE MEDICINE CUP
In order to add a medicated vapor to the "mist" output:
1. Turn the POWER switch to the "OFF" position and allow the steam diffuser to cool.
2. Carefully add liquid medicine to medicine cup. DO NOT fill the cup more than half full.
3. Carefully place medicine cup on top of steam diffuser
4. Turn the POWER switch to either the LO or HI position.
5. After use, remove the cup from the unit and clean any residue from the cup with
warm water.
WARNING:
DO NOT use any liquid medicine other than those specifically recommended for use
with a steam vaporizer or warm mist humidifier.
DO NOT pour medicine directly into the steam diffuser openings nor add it to the
water in the tank or tray.
MINERAL ABSORPTION PAD INSTRUCTIONS
Warm mist humidifiers do not spread fine mineral dust into the air that you breathe
nor on your furniture, the way that other type humidifiers do. The mineral dust remains
trapped in the humidifier hot water reservoir. Use of mineral absorption pads will
play a major role in capturing and removing minerals from hot water reservoir, and
preventing a stubborn mineral buildup. The unit can run without pads, but more
frequent cleaning will be required. The Mineral Absorption pad that fits your unit is the
EMP-15P
1. Before starting humidifier, place mineral absorption pad in the hot water reservoir.
After the humidifier has been operating, the water will become HOT, and CAUTION
should be exercised when handling mineral absorption pad. It is best to allow
humidifier water to cool down, and to use tongs or long tweezers when handling pad.
2. The useful life of the mineral absorption pad will vary, depending on the mineral
content of the water used. In areas of moderate mineral content water supply,
the mineral absorption pad should be changed after approximately (3) weeks
of continuous use. If the water is "Hard Water", the pad should be changed more
frequently. The best way to tell when the pad should be changed is to examine it
AFTER the water has cooled down, to see if it is still soft and pliable. When the pad
is near the end of its life, it becomes stiff and hard and should be replaced with a
new pad. Another sign to change pad is when scale begins to buildup on interior of
hot water reservoir. If pad appears to disintegrate (normally due to use of softened
water) discontinue use of pads.

CLEANING AND MAINTENANCE

Water contains minerals and other particles. During operation most of these minerals
will remain in the water reservoir. Gradual buildup of deposits will coat the hot water
reservoir and reduce its efficiency. The importance of routine cleaning and care cannot
be over-emphasized. Hard water contains more minerals and other particles.