The alarm module has 5 LEDS and a buzzer.
The LEDs only come on if a fault has been detected.
1/ The 3 red "motor alarm" and "general alarm" LEDs mirror
operation of the corresponding LEDs on the base board.
2/ The yellow "HF reception" LED mirrors operation of the
yellow mains power supply LED on the base board:
- On steadily = transmission OK, base board powered by
the mains supply
- Flashing = transmission OK, but mains power supply fault
on the base board (which is thus operating on its battery
power supply)
- Off = no HF reception from the base board = loss of HF
signal, or base board battery flat, or base board failure.
3/ The green "mains" LED shows the status of the power
supply for the remote alarm module:
- On steadily = module powered by the mains supply
- Flashing = mains supply fault for the module (which is thus
operating on its battery power supply)
- Off = module failure or module battery flat
4/ The buzzer stays on continuously during an alarm.
It stops if the alarms are no longer present or if you press
the button "Reset" General Alarm.
CONFORMITY WITH STANDARDS
1 0
Pro complies with standard EN 12050-1 (lift
station for household waste containing faeces) and with the
• SANICUBIC
®
European directives covering construction products, electrical
safety and electromagnetic compatibility
This unit must be installed and used in compliance with
European installation standard EN12056 and with local
requirements.
1 1
COMMISSIONING
1- Once the plumbing and electrical connections have been
made, check that the connections are watertight by
letting water flow successively through each inlet used.
Make sure that the unit is operating correctly by carrying
out at least two start cycles with water to test the system.
2 -
WARNING!
Do not operate the motors in override
status (by pressing the pushbuttons
on the control box) until the pumps have been filled
with water. Operation without water damages the
maceration system.
USE
1 2
Pro unit is designed to drain off
household waste water. Any other use will invalidate the
1- The SANICUBIC
®
guarantee. Do not dispose of sanitary towels, condoms,
hygiene articles, oils, solvents, acids, or any other poten-
tially corrosive or explosive liquids etc., via the unit.
2-
WARNING: In the event of a power failure, stop
draining any water from the equipment connected
to the SANICUBIC Pro unit.
3- Do not install or use the unit in a zone where there is a
risk of explosion.
1 3
MAINTENANCE
A visual check of the lift station must be made once a month
to make sure it is operating correctly, and the installation
must be inspected regularly (once a year) by a qualified
person. Meanwhile if encounter technical problems, please
ask our after-sales service for advice. If the power supply
cable of the unit is damaged, it must be replaced by the
manufacturer or its after-sales service to avoid all danger.
GUARANTEE
1 4
Pro unit is guaranteed for two years
(parts and labour) provided that it has been installed and
The SANICUBIC
®
used in compliance with the present instructions.