Descargar Imprimir esta página

Acuity Brands JUNO MD1 Instrucciones De Instalación página 2

Mini carcasa led empotrada

Publicidad

Idiomas disponibles

Idiomas disponibles

JUNO TYPE MINI LED RECESSED HOUSING
MD1 & MDS – MINI DOWNLIGHTS
MG1 & MGS – MINI GIMBALS
Step 5. Make certain no bare conductors are exposed after attachment
to terminals. Replace terminal block cover when wiring is completed.
Step 6. Fixtures may also be daisy-chained by routing Class 2 12V AC
wiring from fixture to fixture (Refer to wiring diagram). Always connect
cable wires to adjacent terminals on the far right or far left side of the
terminal blocks. Tighten all terminal block screws to 4 In-lb minimum.
Step 7. Push excess wire into opening in mounting surface, displace
fixture coil springs as shown, (Fig. 4) insert fixture into opening.
Springs will recoil to hold fixture in place. Make certain wires are
contained behind the mounting surface and not damaged in any way.
Step 8. Gimbal fixtures may be adjusted to direct light as desired.
Remove fixture from mounting surface, adjust light aiming by rotating
lower housing to desired position and re-install. Make certain wires are
not twisted or damaged as a result of the re-aiming.
Step 9. Complete installation of all fixtures before restoring
electrical power.
WIRING DIAGRAM
DAISY-CHAINED FIXTURE(S)
(OPTIONAL)
WARRANTY
5-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Technical Services Phone (888) 387-2212
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-recessed
©2017 Acuity Brands Lighting, Inc
INSTALLATION INSTRUCTIONS
Rev 3/17
P2949
Figure 4
12V SECONDARY LEADS
MINI LED DOWNLIGHT
OR GIMBAL FIXTURE
CLASS 2
12V AC OUTPUT
TRANSFORMER
2 of 2