Cycle Count
To display the current cycle count, press the
Start key while the display is showing the
temperature in the sump. The display will
show a 2-digit number indicating how many
cycles have been run to completion (cycles
which were stopped in progress are not
counted). Press the Start key to return to
PROGRAM mode without resetting the count.
Press the Up or Down key to reset the count to
zero and return to PROGRAM mode.
Cycle Programming
To edit an existing cycle or create a new cycle,
press the Up key while the display is showing
the temperature in the sump. The display will
show "CY01." Press the Up or Down key
until the desired cycle number is displayed.
Press the Start key to begin editing the
selected cycle.
Note: The test cycle cannot be displayed or
altered while the computer is in PROGRAM
mode.
All cycle programs ("CY1"–"CY30") can be
customized within a preset program structure.
Each cycle program consists of eight program
segments. See the following table.
Cycle Program Segments
Segment
Display
Prewash
PrE
Wash
UASH
Fill 1
FIL 1
Fill 2
FIL 2
F232087
Segment
Display
Fill 3
FIL 3
Fill 4
FIL 4
Fill 5
FIL 5
Fill 6
FIL 6
Programming
When modifying a cycle, a time must be
entered for each segment. To skip a segment or
spin, set the time to "00" and press the Start
key. The following table gives the time
parameters for each segment and spin, as well
as the allowable temperature range.
Time and Temperature Parameters
Function
Minimum
Prewash
2 minutes
Wash
2 minutes
Fill 1
2 minutes
Fill 2
2 minutes
Fill 3
2 minutes
Fill 4
2 minutes
Fill 5
2 minutes
Fill 6
2 minutes
Intermediate Spin
30 seconds
Final Spin
1 minute
Temperature
75°F / 25°C
Note: Spin times in Prewash through Fill 5
cycle segments are entered in seconds. Spin
time for the Fill 6 cycle segment is entered
in minutes.
1. Press the Up key until the computer
display shows the segment to be edited.
Press the Start key.
2. Prewash segment only. Use the Up or
Down key to select either "PrEU"
(normal prewash) or "FLUS" (overflow
fill prewash). If "FLUS" is selected, the
fill valve(s) will remain on for the timed
duration of the segment. Press the
Start key.
Maximum
30 minutes
20 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
120 seconds
10 minutes
200°F / 93°C