Operation
Cycle Execution
Note: The display pauses the cycle time
countdown during the fill, heat, and
drain steps.
Each of the 30 cycles consists of 8 segments:
Prewash, Wash, and Fills 1–6. A description of
the various steps in a cycle segment follows:
After the Start key is pressed, the door locks,
the drain closes, and the machine begins filling
to the programmed level; each programmed
segment begins with a fill. The display counts
down the remaining cycle time in minutes and
seconds while the cycle is running.
If a supply is programmed in a step, the
supply dispenser will flush during the fill of
that segment.
If the machine is connected to an external
chemical supply system, the programmed
supply will begin 10 seconds into the fill. The
supply will remain on until the programmed
water level is reached, or until 60 seconds have
elapsed, whichever happens first.
If the computer does not receive a signal
that water level has been attained within 30
minutes, it will alternately flash "STOP" and
"FILL" and sound the on-board beeper for ten
seconds; it will then initiate the stop routine.
Spray Rinse
Fill segments 1–5 can be designated as spray
rinse segments on standard models. During a
spray rinse segment, the basket rotates at
18
(Continued)
Fill
extract speed while the spray rinse nozzle
mounted in the door sprays a fan-shaped
stream of cold water into the basket.
Wash
Standard Wash
As soon as water level is reached (and any
programmed temperature is reached), the
displayed time begins counting down at one-
second intervals.
All but three cycles use the standard wash
agitation. This agitation repeats for the first
programmed time duration in the prewash,
wash, and fill segments.
The standard wash agitation sequence:
• 12 seconds counterclockwise at
wash speed
• A 3-second pause
• 12 seconds clockwise at wash speed
• A 3-second pause
Note: While a cycle is in progress, pressing
and holding the Start key will cause the
current cycle number to be displayed. Pressing
and holding the Up key while a cycle is
running will display the temperature inside
the sump.
F232087