General Specifications - EGAmaster EGATronik 51664 Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

Caution, possibility of electric shock
Altemating current
1. Max display: 4099.
2. Polarity display: Auto.
3. Overload display: "OL" or "-OL".
4. Low battery indication: The
5. Low battery shutdown prompt: The "Lo.bt" interface appears on the LCD and lasts for about
1 Os, the buzzer beeps three times, and the meter automatically shuts down.
6. Test position error: lf the source under test is not placed at the center of the clamp jaws
when measuring current, ±1.0% additional error in reading will be produced.
7. Drop protection: 1m.
8. The maximum size of jaw opening: 28mm in diameter.
9. Battery: AAA battery 1.5Vx2.
10. Auto power off: lf there is no operation of the function switch or any button for 15 minutes,
the meter will automatically power off. This function can be turned off as needed.
11. Dimensions: 215mmx63.5mmx36mm.
12. Weight: About 248g (including batteries).
13. Altitude: 2000m.
14. 0perating temperature and humidfy: 0ºC-30ºC (≤80%RH), 30ºC-40ºC (≤75%RH), 40ºC-
50ºC (≤45%RH).
15. Storage temperature and humidity: -20ºC-60ºC (≤80%RH).
16. Electromagnetic compatibility:
RF=1V/m, overall accuracy = specified accuracy + 5% of range.
RF>1V/m, no specified calculation.
18
ELECTRICAL SYMBOLS
Direct current

GENERAL SPECIFICATIONS

symbol is displayed.
Equipment protected throughout
by DOUBLE INSULATION or
REINFORCED INSULATION
Earth (ground) TERMINAL
Warning or Caution