Installation; Hydraulic Connection - Joannes LADY 30S Manual Para La Instalación Y El Mantenimiento

Ocultar thumbs Ver también para LADY 30S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

HYDRAULIC CIRCUIT LADY R
Hydrometer connection
1
2
Sheath for bulbs
3
Automatic air purge valve
Safety valve
4
5
Expansion tank
6
Drain cock
Burner
7
8
Filling cock
9
Circulating pump

INSTALLATION

The boiler must absolutely be installed by qualified experts, according to the manufacturer's indications and in
compliance with all the relative laws and regulations. We particularly recommend that all safety specifications
and regulations regarding the construction and positioning of flues are respected.

HYDRAULIC CONNECTION

Connect the appliance to the water system according to the indications placed near each connection and those
outlined in figure 1 of this manual. Connection must be carried in such a way as to ensure the pipes are free
from tension. The appliance is supplied with an expansion tank. As far as this is concerned, we would like to
remind you that the loading pressure of the system, must fall between 1.2 and 1.5 bars.
CONNECTION TO THE FLUE
We recommend you connect the boiler to a good flue, constructed according to the regulations in force. The
pipe between the boiler and the flue must be made of a material specifically designed for this purpose, or in
other words, resistant to high temperatures and corrosion. Make sure that any joints are well sealed and apply
thermal insulation to the entire pipe between the boiler and chimney in order to avoid the formation of conden-
sate.
9
8
7
6
1
2
3
17
4
5
fig. 5