Ci-30 KS S-30MP1 IS 15803:2008 AS/NZS 1716:2012 EN 13794:2002
RECOMMENDATIONS FOR USING,
RECORD-KEEPING AND HANDLING
Perform visual inspection and check for leakage Ci-30 KS using UPG prior to putting into service.
Appropriate unique number for deployed SCSR and record this information into «Mine registration
log book for self-contained self-rescuers». SCSR may be used by each worker individual or by
separate production sections.
Reserve (not individual) SCSR recommended to record in «Mine registration log book for reserved
self-contained self-rescuers for mine workers and outside organizations».
Service life will be calculated from the date of manufacturing indicated on coupling strap if there
is no information in «Mine registration log book for self-contained self-rescuers».
Take SCSR from lamp room and perform visual check in accordance with «PRIOR TO USE» prior
to descending into the mine.
It is prohibited to leave SCSR close to heat-radiating devices, wash by water and use as support
arrangement and sitting. It is allowed to clean SCSR with wet cloth.
DONNING PROCEDURE
Immediately don the self-rescuer in case of emergency (sudden release of gas, fire, explosion).
Donning procedure:
Step 1:
•
Inhale and hold your breath.
•
Put the self-rescuer in front of you.
10
DEZEGA