Change-Over Procedure; Training - DEZEGA Ci-30 KS S-30MP1 Serie Manual De Usuario

Un auto-rescator aislado de oxígeno químico para escape
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 76
Ci-30 KS S-30MP1 IS 15803:2008 AS/NZS 1716:2012 EN 13794:2002

CHANGE-OVER PROCEDURE

If it is necessary to don a new oxygen self-rescuer during escape, proceed as follows:
Take a new self-rescuer, sit or kneel down.
Continue breathing from the old oxygen self-rescuer and hold it on your lap.
Take off the helmet and unfasten neck and chest strap.
Open a new self-rescuer according to «Donning procedure», Step 2.
Take a deep breath from the old self-rescuer, remove the old mouthpiece and nose clip,
quickly don the new self-rescuer, adjust the neck strap, fasten the chest strap and continue
going to a place of safety in accordance with Steps 3-7.

TRAINING

WARNING!
Training is obligatory. Only a trained user can use Ci-30.
It is recommended to perform first training under the supervision of qualified instructors in training
room.
The user's training program should include knowledge of this manual and practical exercises for
donning apparatus, belts adjustment and walking with the apparatus.
A Training self-rescuer is available and should be used for regular trainings and refresher training.
Attainments of breathing with SCSR need regular training and consolidation of knowledge.
Insufficient training may cause panic in case of emergency and inhalation of dangerous gases
from irrespirable atmosphere. To avoid panic reaction we strongly recommend performing training
using Training device with disposable breathing training kits for 15 or 30 min of duration.
Training device with training regenerative cartridge completely imitate donning and breathing
conditions of real SCSR.