ENGLISH
Table of Contents
4.0 Installation ............................................................. 17
6.0 Maintenance ......................................................... 20
7.0 Servicing ................................................................ 21
troubleshooting ............................................................ 21
Figures .......................................................................... 56
16
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including thosethat refer to national and
European standards, shall be complied with when installing
the product.
Instructions for mounting, installation and use are enclosed
with the product. Prior to using the product the installation
must be inspected by a qualified person.
A product data label in heat resistant material is located on the
heat shield at the back of the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material:
Cast iron
Finish:
Paint
Fuel:
Wood
Log length, max.:
35 cm
Operating range:
3,2 - 11 kW
Draught system:
Air wash system
Combustion system:
Secondary combustion
Flue outlet:
Top.
Flue dimension:
- inside :
Ø 150mm/177 cm
section
- outside :
Ø 175 mm/240 cm
section
Approx. weight:
132 kg
Product measurements,
fireproof walls etc.
See fig.1
Technical data according to EN 13229
Nominal heat output:
Smoke gas mass flow:
Recommended chimney draught:
Effiency:
CO emission (13% O
):
2
Flue gas temperature:
Operating mode:
2
cross
2
cross
8,0 kW
8,7 g/s
12 Pa
73%
0,128%
0
C
322
Intermittent