Enabling "Manual Setting" Mode
A battery model is shown in the following example. These
instructions apply to all models. After 30 minutes, the "Man-
ual Setting" mode will be disabled automatically and all set-
tings will be saved.
Prerequisites
• Water supply valve is open
• Battery is full (LED does not blink) for DC faucets
• AC power is on for AC faucets
Remove shut-off screw
1
Remove mixer handle (only for faucets with external mi-
2
xer)
Remove housing vertically
3
Remove battery from battery holder
4
The following procedure (a, b, c) must be done three (3)
times in a row.
a - Re-insert battery
5
b - LED lights up
c - Remove battery immediately after LED switches off
a
Insert battery
6
Mount housing vertically
7
Mount shut-off screw
8
11
c
b