- Alarms: it is possible to establish minimum and maximum speed thresholds. The parameter will start flashing and the acoustic alarm will be activated
when speed rises above or drops below the thresholds. In display mode, you can deactivate the acoustic alarm by pressing
condition will keep flashing until the corresponding value is within the permissible range.
6.3 – TANK MENU
The tank can be calibrated and all relative settings stored in DATA-MATE. Calibration can be performed in manual or automatic mode. To perform this
procedure correctly, use clean water and make sure the tank is placed on a flat surface.
6.3.1

MANUAL CALIBRATION

In order to establish the tank's volume, you can measure and set up 50 detection points at the most. A lower number of points will reduce the level
of accuracy of the subsequent readout. The last setting to enter during calibration is the maximum volume of the tank. During calibration, always use
clean water.
CALIBRAZIONE
Manuale
Automatica
Reset
- Connect the level sensor to DATA-MATE. Press
- Check the STEP 1 - LEVEL 0 data displayed. Press
the level sensor with respect to - for instance - the pump's suction pipe);
- Press
to go to STEP 2;
- Prepare a known amount of liquid (measure its quantity in litres) and pour it into the tank;
- Press
. The level and pressure settings will start flashing. With
tank;
- Press
to save calibration STEP 2;
- Press
to go to the next calibration step, namely STEP 3;
- Prepare a known amount of liquid (measure its quantity in litres) and pour it into the tank;
- Press
. The level and pressure settings will start flashing. Press
manual mode;
- Press
to save calibration STEP 3;
- Repeat until you have reached the maximum capacity of the tank.
By pressing
+
keys at the same time, is possible to quit the selected calibration step only if the value is still flashing.
DATA-MATE will automatically display the value entered by the operator during the last STEP. The operator must check the total quantity poured into
the tank. Perform these operations with care and remember to keep a back-up copy of tank calibration (use the USB menu described in § 6.1.5).
200.1012.15
;
(in the example, the value is 3 mbar. This can be checked. It depends on the position of
or
, enter the quantity of liquid in litres that you have poured into the
to enter the total quantity (STEP 2 + STEP 3 in litres) inside the tank, in
12 / 22