-To reduce the risk of an injury from injection, splashing fluid, moving parts,
or follow the pressure relief procedure whenever you are instructed to
relieve the pressure, stop dispensing.
-Check or service any of the system equipment, or install or clean the
nozzle.
-To reduce the risk of serious bodily injury, including fluid injection,
splashing in the eyes or on the skin, or injury from moving parts, always
follow this procedure whenever you shut off the pump, and before
inspecting, removing, cleaning or repairing any part the pump or system.
1.Close the supply pump's bleed-type master air valve (required in
pneumatic systems).
2. Open the dispensing valve until pressure is fully relieved.
3. Open the fluid drain valve at the pump fluid outlet. Leave the drain valve
open until you are ready to use the system again.
Notes:
If you suspect the dispensing valve, extension or grease fitting coupler is
clogged, or that pressure has not been fully relieved after following all the
previous steps, using a rag very slowly loosen the coupler or hose end
coupling and allow pressure to be relieved gradually, then loosen the part
completely. Now clear the clog.
TECHNIQUE PARAMETER
Technique Parameter of Digital Grease Control Valve
MODEL
BZ-2000
WORKING PRESSURE
0.5 - 600 BAR
MÁX. 60ºC
WORKING TEMPERATURE