The controller measures the ambient temperature to determine
the charging voltage. Controller and battery must be installed in
the same room.
The controller warms up during operation, and should therefore
be installed on a non flammable surface only.
REMARK: Connect the controller by following the steps described
below to avoid installation faults.
1
A DIN Rail mounting plate is available as an accessory (CX-DR2).
This allows mounting the controller on a standard 35mm DIN rail.
Remove the screws at the backside of the controller and screw
the mounting plate with the long fastening screw onto the backside
of the controller.
Mount the controller to the wall with
screws that fit to the wall material.
Use screws with 4 mm shaft and max.
8 mm head diameter, no counter sunk.
Mind that the screws have to carry also
the force applied by the wiring.
Make sure that the ventilator slits on
the sides are unobstructed.
21