If you do not want to set it, leave the variable blank.
currency = ;
timeout_remote_validation
This variable is set by the central administrator and is not configurable locally.
client_type
Defines the client type numerically. Unless the manufacturer has indicated a specific client type, this field is
factory-set to 0.
client_type = x;
load_management
This variable is enabled automatically if the installation has a Dynamic Load Management system. It can be
disabled by setting it to 0.
load_management = 0;
ac_phase_outlet1
Defines the phase of the power supply connected to the R phase of the station's current outlet 1, and also if the
station is powered in single-phase or three-phase. This variable can be set to the following values:
1: Phase R
2: Phase S
3: Phase T
5: Phase R (three-phase connection)
6: Phase S (three-phase connection)
7: Phase T (three-phase connection)
Example:
ac_phase_outlet1 = 1;
ac_phase_outlet2
Defines the phase of the power supply connected to the R phase of the station's current outlet 2, and also if the
station is powered in single-phase or three-phase. This variable can be set to the following values:
1: Phase R
2: Phase S
3: Phase T
5: Phase R (three-phase connection)
6: Phase S (three-phase connection)
7: Phase T (three-phase connection)
Example:
ac_phase_outlet2 = 1;
fw_version
This variable displays the firmware version. It is not editable.
build_number
This variable displays the build number. It is not editable.
4.3. Sessions
This folder houses the files that contains all the information relating to the charging sessions of the device and the
important warnings, alarms and events that have taken place.
12
Folder system
ABA2020IQM05_A - Configuration