Inappropriate Use - DEA SYSTEM Spazio 702S Instrucciones De Uso Y Advertencias

Operador electromecánico para puertas seccionales
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

WARNING The use of spare parts not indicated by DEA
System and/or incorrect re-assembly can create risk to people,
animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System
and scrupulously follow all assembly instructions.
4.6
Training
After installation and setting, the correct operation of the
complete automatism must be carefully illustrated to the final
user. The SPAZIO gate operator requires careful instruction on
the release mechanism (see "Enclosures") in particular and the
respective maintenance schedule (see Point 4.5.6.).
WARNING Awareness of the operation of the SPAZIO
release mechanism (see F9 Page 48) is essential for all users
of the automatism because the failure to use the device quic-
kly during emergencies can jeopardise people, animals and
property. Enclosure I to these instructions, which the installer
is required to deliver to the final user, illustrates operation and
can be detached.
4.7

Inappropriate use

Chapter "4.4 Appropriate conditions of use" describes the
conditions for which the product has been designed and tested.
The product must never be used for other purposes.
WARNING The use of the product under unusual condi-
tions not foreseen by the manufacturer can create situations
of danger, and for this reason all the conditions prescribed in
these instructions must be respected.
5 WIRING AND CONTROL
Centrale724RR
Centrale124RRZ
SPAZIO 702S
SPAZIO 703S
1-2
1-2
24 V
24 V
/
3-4
24 V Batt
/
5-6
LC/SCA
13-14
7-8
LAMP
LAMP
13
9
COM
COM
13-12
9-10
+24VAUX
+24VAUX
13-11
9-11
+24VSIC
+24VSIC
3-4
12-13
M
J3
14
FCA
J3
15
FCC
5
16
START
START
6
17
CHIUDE
PEDON
7
18
STOP
STOP
8
19
FOTO
FOTOC
9
20
SIC
SIC
10
21
COM
COM
15
22
16
23
Operating instructions and warnings
24 V
transformer power supply input (faston BLU)
24 V
battery power supply input (Follow carefully polarity indications)
Free contact max. capacity 5 A : this contact can be used to control an open gate war-
ning light (P27=0) or a courtesy lamp (P27≠0)
Flashing light output 24 V
not demand the use of a flashing light card.
Common safety devices / Connection of motors metallic parts
+24 V
power supply output for auxiliary circuits and uncontrolled safety devices To
be used as power supply of any auxiliary devices, photocell receivers (in all cases), and
of safety devices when testing these latter before each operation
+24 V
power supply output for controlled safety devices. To be used as power
supply of photocell transmitters (in all cases) and of safety devices when testing these
latter before each operation
Motor output 24 V
M
N.C. input limit switch while opening.
N.C. input limit switch while closing.
N.O. open input. If activated, it opens or closes both motors. It can work in "reversal"
mode (P25=0) or "step-by-step" mode (P25=1)
PEDESTRIAN/CLOSE N.O. input. If it is set off it may: partly open the door (If P030>1);
close the door (If P030=1); close the door in all cases (If P030=0)
N.C. stop input. If activated, it stops the movement of both motors during any opera-
tion. If unused, short circuit to common
N.C. Photocell input. In case of activation it reverses the movement only while closing
(P26=0) or it reverses the movement while closing and stops while opening (P26=1). If
unused, short circuit to the common
N.C. leaf safety device input. In case of activation it reverses the movement (P18=0) or
it stops it (P18=1). If unused, short circuit to the common
Common inputs
Aerial ground input
Aerial signal input
BOARD PROGRAMMING
5.1
Wiring and terminal board connections
Connect to the power supply 230 V ~ .± 10% 50 Hz through
a multi pole switch or a different device that can ensure multi
pole disconnection from the power supply, with a contact ope-
ning of 3 mm. Ake all connections to the terminal board and re-
member to short-circuit, whenever necessary, all unused inputs.
(See table 1 terminal board connection and page 43 basic and
complete wiring diagram)
5.2
Programming
After making all connections to the terminal board, remember to
short-circuit, whenever needed, any unused input (see "connec-
tion to the control board") and power the card: on the display
you will read for a few seconds "rES-" followed by the symbol
"----" which stands for gate closed.
•• Visualisation of inputs status
Press on the "OK" key to check if all inputs have been properly
connected.
By pressing on the "OK" key when the control board awaits fur-
ther instructions ("----"), the display shows some vertical seg-
ments: each one of them is associated to one of the control
board inputs (see the picture above). When the segment is
lighted it means that the contact associated to it is closed, on
the contrary, when it is switched off the contact is open. You can
Table 1 Terminal board connection
max 15W art. Lumy 24S The intermittent output does
max 70W
S P A Z I O
13

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spazio 703s

Tabla de contenido