PROCEDURE DESCRIPTION
Positioning of the door/gate
Unused parameter
Memorization of the motors' stroke
Deletion of the radio receiver memory
Transmitters memorization
Search and deletion of a transmitter
Resetting of default parameters
PARAMETER DESCRIPTION
Type of coding of the radio receiver
Channel selection and linking to "start" and "pedestrian" inputs
Motors' speed during normal stroke (calculated as % of max speed)
Motors' speed during slow-down phase (calculated as % of max speed)
Slow-down duration (expressed as % of total stroke)
Unused parameter
Motor's force while opening (if = 100 --> max force, sensitivity on obstacle excluded)
Motor's force while closing (if = 100 --> max force, sensitivity on obstacle excluded)
Unused parameter
Unused parameter
Selection of type of external safety device: rib / barrier. If the "rib" modality is selected, the SIC
input activation inverts the movement direction; during slow-down phase, while if the "barrier"
modality is selected the movement is stopped.
Time of automatic closing (expressed in sec). If = 0 the automatic closing is deactivated
Time of pre-flashing (expressed in sec)
Unused parameter
Unused parameter
Collectivity function: if it is activated it deactivates both start and pedestrian inputs for the
whole duration of automatic opening and closing
Ram blow function: if it is activated, it pushes the motors closed for one second before each
opening movement, so as to ease motor's start
Operating program: reversal (start->open, start->close, start->open ...),
(start->open, start->stop, start-close...)
Photocell function even while opening: if it is activated, the photocell stops the movement while
opening until the obstacle is removed. In any case it reverses the direction of movement while
closing
Clean contact operation:
- If = 0, open gate fixed warning light, the contact is always closed when the gate is moving
or opened, it opens again only when the closing movement is completed
- If =1, open gate intermittent light, the contact is slow while opening and fast while closing,
always closed when the gate is opened, it opens again when the closing movement is
completed
- If>1 courtesy light, the contact is closed during every movement, it opens again when the
motor stops according to a pre-settable delay (expressed in sec)
Short reversal at end of stroke: when the door/gate reaches the end of stroke, it reverses shortly
the movement so as to "release" the mechanical stress due to the door/gate pressure on the
end of stroke itself
Unused parameter
" PED " input functioning
-If=0, it ensures the door or gate closing in any position, "AP" input works normally.
-If=1 the "PED" input starts the closing while "AP" starts the opening.
-If=2 the "PED" input (permanent command) starts the closing, the "AP" input (permanent
command) starts the opening. The gate stops at release.
-If>2 "PED" starts the pedestrian opening. The selected value indicates the duration of the
pedestrian stroke (expressed as a % of the total stroke). The "AP" input normally works.
Ramps-up rate
-If=0 The motor starts immediately at the selected speed
-If=1 The motor speeds up progressively until it reaches the selected speed
Reaction at detection of an obstacle while opening
-If=0 the door reverses travel direction
-If different from 0 the door reverses travel direction only for the time set (expressed in sec)
Reaction at detection of an obstacle while closing
-If=0 the door reverses travel direction
-If different from 0 the door reverses travel direction only for the time set (expressed in sec)
Unused parameter
The default value, set by manufacturer at the factory, is written in bold and underlined.
1
Column reserved to the installer to fill in with the automation personalised parameters
2
Inactive channel.
3
Operating instructions and warnings
SETTABLE VALUES
step-by-step
S P A Z I O
USER
1
HCS fixed part only
HCS rolling code
HT12E dip switch
start pedest.
start pedest.
1
2
3
4
CH
CH
CH
CH
1
3
4
1
CH
CH
CH
CH
1
4
4
2
CH
CH
CH
CH
2
1
4
3
CH
CH
CH
CH
2
3
1
2
CH
CH
CH
CH
3
2
4
2
2
3
CH
CH
CH
CH
3
1
3
2
3
CH
CH
CH
CH
3
2
4
2
3
CH
CH
CH
CH
"safety rib" mode
"photoelectric barrier" mode
deactivated
activated
deactivated
activated
reversal
step-by-step
Photocell activated only in closing
Photocell activated also in opening
open gate fixed warning light
open gate intermittent warning
light
courtesy light with settable delay-
off
deactivated
activated
Central lock
Separate lock
Man present command
Pedestrian
fast ramp
slow ramp
Table 2 Parametres
2
17