Deviations From Regular Operation; Abort / Termination Of Programme; Exchanging The Device Fuse; Resetting The - Dreve Vacfomat V9 Instrucciones De Trabajo

Máquina de termoformado de vacío para la tecnología de alineadores
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Vacfomat V9

8. Deviations from regular operation

8.1. Changing specified times
The specified times can be prolonged
or shortened individually if required.
For this purpose, the new time to be
entered is changed by means of the
rotary/push button (3) until the new
time is shown on the display (4) in
flashing mode. Before it is used for
the first time, it must be approved by
the operator by pressing the rotary/
push button. The time shown will no
longer flash. The new time programme
is now ready for operation.

8.2. Abort / termination of programme

It is possible to abort/terminate all
actions of the Vacfomat V9 by press-

9. Exchanging the device fuse

Disconnect the device from the mains
supply by pulling out the mains plug
of the power cable. The fuse carrier is
located on the left side of the device,
integrated in the mains supply. In order
to check or exchange the fuses, push
and hold the push catch of the car-
rier and remove the carrier from the
device.
Pull the defective fuse out of the clamp
bracket by applying slight traction and
replace it by a new, equivalent fuse.
34
34
Tip:
The performance of the heating may
decrease slightly after 2000 operat-
ing hours. By prolonging the heating
times by five to ten (5–10) seconds,
optimum thermoforming results can
be attained again.
The specified times are average values
and intended for general use.
In case of extreme undercut areas
or very high models, a prolongation
of the heating time can optimise the
results.
ing the rotary/push button (3) for at
least two (2) seconds.
Only use the fuse strength
specified on the back.
After the fuse has been exchanged,
insert the fuse carrier into the housing
by applying slight pressure until you
notice that the fixation has engaged.
10. Resetting the temperature monitor / exchanging an
infrared heating element
Before accessing the inner parts of the device, the mains plug must
be pulled out.
10.1. Resetting the temperature monitor
The temperature monitor checks the
ture. In the centre on the back of the
ambient temperatures of the heating
Vacfomat V9, there is an opening
tubes and the heating cover. If the
closed with a plastic cover between
temperature rises on the inside of the
the two fans. Carefully remove the
heating cover to a value > 65°C dur-
plastic cover, insert an approx. 6–7 cm
ing the heating process, the temper-
long rod (e.g. screwdriver) into the
ature monitor will be activated and
opening and press it against the
disconnect the heating tubes from the
reactivation button of the tempera-
mains for safety reasons. The function
ture monitor at the end until it has
indicator for the heating (5a) will go
engaged again.
out and the ongoing thermoform-
ing process cannot be completed. In
Then connect the device again to the
order to reactivate the device, allow
mains.
it to first cool down to room tempera-
10.2. Exchanging an infrared heating element / tempe-
rature limiter
The heating elements and/or the
If necessary, separate instructions for
temperature limiters may only be
exchanging these spare parts can be
exchanged by qualified electricians.
requested from Dreve Dentamid.
35
35

Publicidad

Tabla de contenido
loading

Tabla de contenido