4.4

Protection against manipulation

The inside or outside unit of the in-wall or on-wall version are paired at the
factory. If a hardware component is replaced, the pairing must be triggered
again by pressing the "Pairing" button on the inside unit. The yellow LED
goes out if the pairing is performed successfully.
4.5

Display and operating elements

4.6

Connection to radio module I/O

An outside unit can directly communicate with a radio module I/O (from
firmware version 03.00) via an encoded bus. For connection of the radio
module I/O and outside unit we recommend using a telecommunication
cable, type J-Y(ST)Y 2x2x0.8.
Lights up continuously, if
Connection LED
connection with the outside
unit is OK
Lights up to indicate its readi-
LED
ness to pair
Pairing
Push-
but-
Terminates pairing
ton
Lights up during a deletion
LED
operation
Delete
Push-
Deletes all fingerprints (also
but-
master fingers), the master
ton
code remains
Lights up when the relevant
Relay 1/2
LED
relay is actuated