Installation and operating instructions
B-55600-20-1-8 | B-55600-20-4-8 | B-55600-23-1-8 | B-55600-23-4-8
Fingerprint scanner and code keypad
5.
You can now decide whether you would prefer to scan the user fingers
without remote control or whether you would prefer index-based operati-
on of the remote control. The first three fingers to be scanned are master
fingers. These are used for administration of the system.
The advantage of normal mode is that you do not require a remote control
to scan new user fingers.
The advantage of the "index administration" mode is that individual user
fingers can be deleted systematically.
You can change the fingerprint scanner module over from standard mode
(default) to index administration mode.
The changeover is only possible in the delivery condition (all LEDs light up).
If you have already taught-in fingers in normal mode, you must perform a
factory reset before the changeover. All saved information is lost in this
case.
5.1
To change over to index administration mode, hold the remote control
directly in front of the blue LED of the module.
99 » OK » 51 » OK
99 » OK » 50 » OK
NOTE
EN
64
Operating advices for fingerprint scanner
Changeover to index administration/normal operation
Changes a module over to
index administration
Changes a module over to
standard mode
Following a reset, the operating mode retains.
07.2017 | XX | Designed in Germany