10 Troubleshooting
9.3 Cleaning the wire guide
10 Troubleshooting
Fault
Problem when mounting
the cable assembly into
the iSTM mount
Hose assembly makes
ripples in the robot axis
Inaccurate
torch reset
Tab. 8
Troubleshooting
EN - 20
Fig. 9 Mounting the wire guide on page EN-16
During maintenance and cleaning, check the O-ring (6) for damage and
replace it if necessary.
NOTE
• If the measures described below are not successful, please consult your
dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
Cause
• No grease on the O-rings of the
adapter
• The cable assembly adapter is not
correctly inserted into the module
• Cable assembly too long
• Dirt deposits in the housing
• iSTM mount damaged
Solution
• Lubricate the O-rings with grease
• Use the cable setting tool
• Align the guide groove
• Change the feeding system
positioning, if possible
• Remove dirt deposits and clean
the housing
• Seal if off with bellows
• Check by specialized personnel