Technical Data; Introduction And Performance Data; Introduction; Performance Data - DENTSPLY MULTIMAT C Instrucciones Para El Uso

Horno de cocción
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1.2 Technical data

Diameter:
Height:
Voltage:
Frequency:
Performance:
Weight:

2 Introduction and performance data

2.1 Introduction

Dear customer,
Thank you for purchasing the Dentsply Multimat C.
This furnace represents an advanced product of the Multimat
series.
Simple and direct operation allows for quick training times.
The Multimat C can store up to 99 customised programs.
7 factory-preset programs can be allocated to program numbers
92 – 98 if required.
All firing data is shown on an illuminated display.
All firing processes are controlled by microprocessors.
Due to its small base, the Multimat C can be set up even in
limited space.
The instrument complies with all valid EU directives and VDE
safety regulations.
Please read the operating manual !

2.2 Performance data

• Quartz muffle with freely radiating heat coil. Useable diameter
93 mm, height 67 mm.
• 2 x 24-digit LCD display capable of displaying alphanumeric
characters
• Complete display of firing data
• Membrane keypad
• 99 fully customizable programs
• 7 factory-preset programs (Ceramco 3)
• Intervene to alter a running program
• Change a saved program to an individual special program
• Copy a saved program to another program number
• Firing temperature up to 1200 °C
• Vacuum time up to 99.5 minutes
• Display for theoretical and actual vacuum level
• Adjustable vacuum
• Firing time up to 99.9 minutes
• Drying and preheating time up to 25 minutes
• Temperature increase rate 1 – 120 °C/minute
• View function
• 3 cooling stages
• Rapid cooling programmable and manual
• Display of remaining time until end of firing
• Overheating protection
28
280 mm
590 mm
100, 110, 115, 125, 230 Volt
50/60 Hz
1300 VA without pump
17.5 kg
• Temperature display in Fahrenheit/Celsius
• Muffle monitoring
• High temperature accuracy
• Standby switch for preventing moisture accumulation in the
firing chamber
• Display of hours of operation
• Display of vacuum pump running time
• Language selection (5)
• Error messages
• Automatic continuation of firing after brief power failure
• Unlimited data backup during power failure
• Automatic frequency change
• Acoustic signal, can be disabled
• Correction factor can be entered during the silver test
• Vacuum program to prevent moisture in the fibre insulation
• GS and CE marks

3 Safe use

3.1 Use within specifications
Caution !
The Multimat C was developed and is intended
solely for the purpose of firing dental ceramics.
Dentsply is not liable for any damage resulting from non-
specified use.
Intended use also includes all notes in this operating manual
as well as all notes in the separate operating manual of the
manufacturer of the vacuum pump.

3.2 Hazards and safety notes

Caution !
In order to ensure safe operation, please observe
the following notes:
Do not set up furnace and vacuum pump next to heat sources.
The distance to the next wall should be at least 25 – 30 cm.
The surface should be non-flammable, and there should be no
flammable objects nearby.
Place the vacuum pump in a well ventilated place. Vacuum
pumps lubricated with oil should always be set up in a lower place
than the furnace.
Do not touch parts that become hot, particularly the cover.
Prior to powering up, ensure that the mains power corresponds
to the voltage specified on the instrument.
After any extended inactivity period, at high humidity or low tem-
peratures, it may no longer be possible to generate a sufficient
vacuum. In this case, preheat the furnace to approx. 1000 °C and
afterwards allow to cool down to idle temperature with opened
firing chamber using the rapid cooling function.
If the furnace is under vacuum in "Off" state for an extended
period of time, the O-ring of the lift plate may adhere slightly.
When heating the firing muffle, there may be vibration noises from
the heater coil.