Descargar Imprimir esta página

Eaton E5524E0402 Instrucciones De Puesta En Servicio página 6

Contador indicador electrónico

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.8 End of programming
6
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
Electronic totalizer and time meter
E5524E0402:
basic operating mode
1. Description
• 6 digit totalizer and time meter with Reset
function
• Red LED display, character height 8 mm
[0.31 in.]
• Display range 0 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Time meter operating modes:
– Counting while INP B is inactive "GAtE.Lo"
– Counting while INP B is active "GAtE.hi"
– Count Start/Stop with INP B edge B
"Inb.Inb"
• Counting ranges: h; min; s; h.min.s
2. Inputs
INP A
Dynamic count input for the totalizer.
INP B
Start-/Stop or gate input for time meter
(independent of the input mode)
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can
be adjusted individually for the totalizer and the
time meter.
3. Selection of the displayed value
Pressing the right key allows switching between
the totalizer display and the time meter display.
Press the key briefly to display the current func-
tion ("total" or "time") for 2 seconds. If, during this
period of time, the right key is pressed a second
time, the device switches to the next function
and displays a confirmation ("total" or "time") for
2 seconds. Then, the value of the selected func-
tion is displayed.
MN05401010E

Publicidad

loading