4.10 Display mode (frequency meter)
4.11 Max. time to wait until "0" is displayed
(frequency meter)
This parameter indicates, how long it takes,
when measuring is active, until "0" is displayed.
4.12 End of programming
4
Value conversion and
display in 1/s
Value conversion and
display in 1/min
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
Electronic display counter with
2 totalizing ranges
E5524E0402:
basic operating mode
1. Description
• 6-digit display counter with Reset function
• Red LED display, character height 8 mm
[0.31 in.]
• Display range 0 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
2. Inputs
INP A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can
be adjusted individually for Counter 1 and
Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of totalizer 1 and the display of
totalizer 2. Press the key briefly to display the
current function ("total1" or "total2") for 2 sec-
onds. If, during this period of time, the right key
is pressed a second time, the device switches to
the next function and displays a confirmation
("total1" or "total2") for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
MN05401010E