Warning
Use only power units which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN
EN 60204−1. Observe also the general requirements for
PELV power circuits as per IEC/DIN EN 60204−1.
Use a closed−loop power unit.
S
To avoid electrostatic discharges and comply with
S
protection class IP54: Seal unused connections with
the protective caps supplied.
Avoiding looping to earth: Use only one of the earth
S
connections (e.g. 6).
Use only these cables (note max. length):
S
Cable
Power supply cable
(V DC)
Motor cable (HME)
Control cable (PLC)
Programming cable (PC) KDI−MC−M8−SUB−9−...
Festo P.BE−K−SFC−LAC−IO 0604NH English
Accessories type ...
KPWR−MC−1−SUB−15HC−...
KMTR−LAC−S50HC−S50HC−... 2,5 / 5 / 10
KES−MC−1−SUB−15−...
Length [m]
2,5 / 5 / 10
(max. 10 m)
(max. 10 m)
2,5 / 5 / 10
(max. 30 m)
2,5
21