Important
The appliance is supplied at an operating vol-
tage 400V/3N (indicated on the sticker ap-
plied to the dataplate); conversion to 230V/3,
can be carried out as described below.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
B
A
C
Remove the test voltage indicator sticker
6)
from the dataplate and apply the new one to
identify the voltage being used.
Important
On completion of the operation make sure
that there are no malfunctions.
3301460_inst_GB_rev.2
CONVERSION OF ELECTRICITY SUPPLY
B
Pull off the knob (A).
1)
Take out the screws (B) and take down the
2)
dashboard (C).
Modify the connections to the heating element
3)
terminals (D) as shown in the electrical system
diagram at the back of the manual.
Fit the jumper (E) to make the electrical con-
4)
nection of the terminals (F).
Replace all when the operation is complete.
5)
D
- 11 -
E
F
GB
ENGLISH