4.
Master Configuration
4.1
Configuration
The DeviceNet Module is a Group 2 slave device, using a predefined master/slave connection set. I/O data is produced and consumed
using polled I/O messaging.
The soft starter must be added to the DeviceNet manager project using the EDS file and configuration/management software tool. This
file is available on the supplied CD or can be downloaded from the website www.controltechniques.com
successfully, the correct EDS file must be used.
Table 4-1 DeviceNet EDS file names
Product
Digistart CS
Digistart IS
An on-screen graphics bitmap file (device.bmp) is available on the supplied CD or can be downloaded from the
website www.controltechniques.com
4.2
DeviceNet polled I/O structure
Once the EDS file has been loaded, the DeviceNet Module must be added to the scanner list with parameters shown in the following
table:
Table 4-2 DeviceNet polled I/O structure
Parameter
I/O connection type
Poll receive size
Poll transmit size
Once the soft starter, module and Master have been set up, configured and powered up, the Master will transmit 2 bytes of data to the
module and receive 14 bytes of data from the module.
5.
Data Structures
5.1
DeviceNet polled I/O output data structure
Master > Slave polled I/O output data is as follows:
Table 5-1 Output data structure
Byte
Bit
0
0
1
2
3 to 7
1
1
0 to 1
2 to 7
1
Only available on Digistart IS soft starters.
2
Ensure that the programmable input is not set to Motor Set Select before using this function.
DeviceNet Module User Guide
Issue 1
SSDM04_11.eds
SSDM08_12_1.eds
.
0 = Stop command
1 = Start command
0 = Enable Start or Stop command
1 = Quick Stop (i.e. coast to stop) and disable Start command
0 = Enable Start or Stop command
1 = Reset command and disable Start command
Reserved
0 = Use soft starter remote input to select motor set
1 = Use primary motor set when starting
2 = Use secondary motor set when starting
3 = Reserved
Reserved
www.controltechniques.com
EDS Filename
Value
Polled
14 bytes
2 bytes
Function
2
2
. In order to operate
7