Quick Reference of Parameters, Alarms and Faults
Description
Param.
P0740 Profibus Comm. Status
P0741 Profibus Data Profile
P0742 Profibus Reading #3
P0743 Profibus Reading #4
P0744 Profibus Reading #5
P0745 Profibus Reading #6
P0746 Profibus Reading #7
P0747 Profibus Reading #8
P0750 Profibus Writing #3
P0751 Profibus Writing #4
P0752 Profibus Writing #5
P0753 Profibus Writing #6
P0754 Profibus Writing #7
P0755 Profibus Writing #8
P0918 Profibus Address
P0922 Profibus Teleg. Sel.
P0963 Profibus Baud Rate
P0967 Control Word 1
20 | MW500
Adjustable
Range
0 = Disabled
1 = Access Error
2 = Offline
3 = Config. Error
4 = Param. Error
5 = Clear Mode
6 = Online
0 = PROFIdrive
1 = Manufacturer
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
0 to 1199
1 to 126
2 = Std. Teleg. 1
3 = Telegram 103
4 = Telegram 104
5 = Telegram 105
6 = Telegram 106
7 = Telegram 107
8 = Telegram 108
0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
5 = Not Detected
6 = 1500 kbit/s
7 = 3000 kbit/s
8 = 6000 kbit/s
9 = 12000 kbit/s
10 = Reserved
11 = 45.45 kbit/s
Bit 0 = ON
Bit 1 = No Coast Stop
Bit 2 = No Quick Stop
Bit 3 = Enable Operation
Bit 4 = Enable Ramp
Generator
Bit 5 = Reserved
Bit 6 = Enable Setpoint
Bit 7 = Fault Acknowledge
Bit 8 = JOG 1 ON
Bit 9 = Reserved
Bit 10 = Control by PLC
Bit 11 to 15 = Reserved
Factory
User
Properties Groups
Setting
Setting
ro
1
0
0
0
0
0
0
0
0
0
0
0
0
1
2
ro
ro
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET