Quick Reference of Parameters, Alarms and Faults
Description
Param.
P0145 Field Weakening Frequency
P0146 Intermediate Frequency
P0147 Low Output Frequency
P0150 Type DC V/f Link Regulator
P0151 DC Link Regul. Level
P0152 DC Link Regul. Prop. Gain
P0153 Dyn. Braking Level
P0156 Overl. Curr. 100 % Speed
P0157 Overl. Curr. 50 % Speed
P0158 Overl. Curr. 20 % Speed
P0178 Rated Flux
P0200 Password
P0202 Control Type
P0203 Special Function Sel.
P0204 Load/Save Parameters
P0205 Main Display Parameter
P0206 Secondary Parameter
Display
P0207 Parameter for Bar
P0208 Ref. Scale Factor
8 | MW500
Adjustable
Range
0.0 to 500.0 Hz
0.0 to 500.0 Hz
0.0 to 500.0 Hz
0 = hold_Ud and dec_LC
1 = accel_Ud and dec_LC
2 = hold_Ud and hold_LC
3 = accel_Ud and hold_LC
339 to 1200 V
0.00 to 9.99
339 to 1200 V
0.0 to 200.0 A
0.0 to 200.0 A
0.0 to 200.0 A
0.0 to 150.0 %
0 = Inactive
1 = Active
1 to 9999 = New
Password
0 = V/f
1 to 4 = Not Used
5 = V V W
0 = None
1 = PID via AI1
2 = PID via AI3
3 = PID via FI
0 and 1 = Not Used
2 = Reset P0045
3 and 4 = Not Used
5 = Load WEG 60 Hz
6 = Load WEG 50 Hz
7 = Load User 1
8 = Load User 2
9 = Save User 1
10 = Save User 2
0 to 1500
0 to 1500
0 to 1500
1 to 65535
Factory
User
Properties Groups
Setting
Setting
60.0 (50.0) Hz
40.0 (33.3) Hz
20.0 (16.7) Hz
0
400 V (P0296 = 0)
800 V (P0296 = 1)
1000 V (P0296 = 2)
1.50
375 V (P0296 = 0)
750 V (P0296 = 1)
950 V (P0296 = 2)
1.1xI
nom
1.0xI
nom
0.8xI
nom
100.0 %
0
0
0
0
2
1
3
600 (500)
cfg, V/f
cfg, V/f
cfg, V/f
cfg
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
HMI
cfg
STARTUP
cfg
cfg
HMI
HMI
HMI
HMI

Publicidad