7.1.2 Connection of 2 x 6 kg (5,1 L) and 2 x 25 kg (21,2 L)
Replace the original caps of the cani-
sters by the optionally available con-
nection hoses (see point 9) and fasten
them hand-tight.
Note that each connection hose must
absolutely be used for the same silicone
component again when changing cani-
sters in the future.
The other side of the connection hose
can now be connected to the machine
with the help of the adapters. Turn the
7.1.3 Connection of the Material Reservoirs
The optionally available material reser-
voirs (see point 9) are clear-transparent
containers, marked with two different
colours for distinction. They are con-
nected to the machine with the help
of the pre-assembled quick couplings.
An electronically controlled float lever
avoids the unwanted complete emp-
tying of the reservoirs. To activate the
system connect the plug-in contacts
7.2 Connection of the Dosper evo to the Electric Circuit
Connect the provided power cord to
the respective socket of the machine
28
canisters upside down and position
them above the machine (a compati-
ble support stand is also available (see
point 9)). Press the connection hoses
onto the adapters (5) until they notice-
ably snap into place.
To allow a problem-free flow of the
silicone mass in the Dosper evo, and
in order to avoid the development of
a vacuum in the canisters, pierce tiny
holes into their bottoms.
mounted to the reservoirs with the
respective sockets (4a/4b) of the
machine.
Take off the lids of the reservoirs and
fill in the respective silicone compon-
ents. Each of the two reservoirs has a
capacity of up to 1. 5 L (corresponds
to approx. 1. 8 kg). Then close with
the lids.
(3), then connect to the electric circuit
7.3 Preliminaries
From the factory the Dosper evo is deli-
The internal pump will press the test
vered with an inactive test liquid inside
mass out of the machine and will
the system. This test liquid must com-
replace it automatically by the con-
pletely be replaced by silicone before
nected silicone.
taking the machine into operation.
Keep the button (7) pressed until both
silicone components are delivered
Turn the machine on at the main switch
evenly out of the mixing head (6).
(1).The illuminated activation button (7)
will light up.
Place an appropriate container under-
The Dosper evo is now ready for
use
neath the mixing head and press the
activation button (7).
7.4 Applying the Mixing Tips
The Dosper evo is equipped for the
match with the triangular bulge of the
application of mixing tips with pink
mixing tip.
closure cap (D-4970-1).
Snap the mixing tip into the guiding
There is a groove at the front of the
and apply to the mixing head (6) by a
mixing head (6). This groove has to
clockwise rotation of 90°.
29