See separate sheet 976 559 (O ptional
Accessories and Nozzle Table)**

Assembly transport cart*

Mounting the axle
23
F ig.
● 1. Insert transport cart axle in case part.
The axle noses must be aligned with
the notches on the case part so that
the axle can be inserted.
2. O nce the axle noses are inserted, the
axle must be rotated through 90°.
3. N ow push the axle through to the
stop on the opposite side.
4. R otate the axle again through 90°.
5. N ow push the axle so far that the
noses on the left and right sides sit in
the notches of the case part.

Mounting the wheels

24
F ig.
● P ush the wheels onto the axle on the left
and right sides. Place a snap-on fastener
on the axle end and push it onto the axle
using a plastic hammer. T he wheels
must be able to turn freely.
Note! S nap-on fasteners can only be re-
moved by destroying them
Mounting the handle
25
F ig.
● Attach the upper curved rod and screw
together with the straight rod piece to
form a complete handle.
26
F ig.
● 1. P osition the handle on the pin of the
case part. Attention! T he handle
must point backwards as illustrated.
2. N ow push the handle down to the
stop on the pin, the detents must en-
gage in both holes.
Position and mount the spraying unit
27
F ig.
● 1. P osition the spraying unit as illus-
trated.
2. S crew spraying unit to handle.
* Available as an accessory or included
in the scope of delivery in units with
compressor connections.

E mptying and Servicing

● O perate the pressure relief valve
(red button) until the unit is no
longer under pressure.
● O pen the pump carefully, at first only a
few turns to the left, to allow any com
pressed air still in the tank to escape.
O nly then should the pump be un-
screwed completely and removed from
the tank.
● C lean the unit thoroughly with water after
each use, rinsing out several times, and
leave open to dry, if possible hanging up
with the opening pointing down.
● S tore the unit in a depressurised condition.
● To clean the filter tube in the quick close
valve: