Appendix 1: Technical Data
Model
Nominal output
Chimney connection (diameter)
Weight
Recommended fuel
Fuel property, max. length
Mass flow of flue gases
Flue gas temperature measured in the measurement section
Temperature measured at the appliance outlet
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
)
2
CnHm emission (13%O
)
2
Particulate emission
Particulate emission in accordance with NS3058-NS3059
Efficiency
Electrical connection
Subject to change because of technical improvements
2576CBSC
10 kW
150 mm
+/- 160 kg
Wood
50 cm
10.1 g/s
285 °C
345 °C
12 Pa
0,06 %
118 mg/Nm³
70 mg/Nm³
19 mg/Nm³
3.44 g/kg
75,9 %
230V, 50 Hz, 0.2 A