Transformer installation:
IMPORTANT WARNING: Locate the breaker on your house power panel that controls the 110/120 Volt AC supply to the wires in the
junction box that you selected to mount the Transformer on. Use a voltage detector, voltmeter or other suitable instrument to make sure that all
power to that junction box is OFF. Identify an existing wiring junction box near the location desired. Verify that the correct wires are available in
this box. There needs to be: Black wire (line or hot), White wire (neutral) and a Green or bare copper wire (ground). The cover plate of that
junction box must have a "knockout". This "knockout" must be removed to make the hole for the stud of the Transformer to mount through.
Thread the Transformer leads through the hole and securely mount the Transformer to the cover plate. Tighten the nut snug only.
WARNING: Over-tightening will break the plastic stud of the Transformer. DO NOT connect the Transformer wires at this time.
Low voltage wiring:
Refer to the wiring diagram below for electrical connections. It is recommended that you leave at least 1' (30 cm) of slack wire at each
component wired to ease future servicing.
WIRING INSTRUCTIONS FOR ZONE MASTER™ DAMPERS
HEAT /COOL THERMOSTAT
OR OTHER SWITCHING DEVICE
W
Y
JUMPER
G
R
The final steps:
Screw the thermostat to the wall.
Connect the Transformer 110/120 Volt wires inside the junction box. See IMPORTANT WARNINGS above!
Connect the GREEN wire from the Transformer to the GREEN or bare copper wire inside the junction box.
Connect either of the BLACK wires of the Transformer to the WHITE wire inside the junction box.
Connect the remaining BLACK wire of the Transformer to the BLACK wire inside the junction box.
Place the cover (with the Transformer mounted to it) on the junction box, making sure that no wires are pinched between the cover and the
junction box.
Now review your installation. If you are positive that everything has been installed safely and securely, you may turn on the breaker on your
house power panel.
MAINTENANCE
Suncourt® recommends that you clean your damper at regular intervals to keep it free from lint, dust and debris. The damper must never be
exposed to temperatures over 140°F (60°C).
OPERATING INSTRUCTIONS
1. Set the switch on the thermostat marked 'ON-AUTO' , 'ON-OFF-AUTO', 'ON-OFF' or similar wording, to the 'ON' position.
2. Heating Season: Set the thermostat to 'HEAT'. Then adjust the thermostat to the chosen temperature (e.g. 55°F). As long as the temperature
in the room is 55°F or higher, the damper will be closed. If the temperature in the room falls below 55°F, the damper will open.
3. Cooling Season: Set the thermostat to 'COOL'. Then adjust the thermostat to the chosen temperature (e.g. 85°F). As long as the temperature
in the room is 85°F or lower, the damper will remain closed. If the temperature in the room goes higher than 85°F, the damper will open.
THREE YEAR LIMITED WARRANTY
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the ZoneMaster™ will, for 3 (three) years from date of original
retail purchase, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a)
manufacturer's liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned,
prepaid, with proof of purchase, well packaged to avoid damage in transit; and (c) this warranty does not apply to defects resulting from the
alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties,
guarantees, and conditions on manufacturer's part, and the manufacturer shall have no tortious or other liability in respect to this ZoneMaster™.
Ship unit to Suncourt Inc. only after obtaining a Return Goods Authorization (RGA) number. Returns without this RGA number will not be
accepted.
Actual product appearance may differ from illustrations. Suncourt reserves the right to modify any or all of its products' features, designs,
components and specifications without notice.
Suncourt® Inc. • 500 W. Second Avenue • P.O. Box 40 • Durant, IA 52747-0040 • 1.800.999.FANS (3267) • www.suncourt.com
STUD MOUNT
TRANSFORMER
TERMINAL
DAMPER UNIT
1. Run one wire from either Transformer low voltage
terminal to either terminal on the Damper.
2. Run one wire from the other Transformer low voltage
terminal to the terminal marked "R" on the thermostat.
3. Run one wire from the other terminal on the Damper
to the terminal marked "W" on the thermostat.
4. Connect the terminals "W" and "Y" on the thermostat
together with a short piece of wire (jumper).
THE WIRING IS NOT POLARITY SENSITIVE
CONNECT EITHER SCREW ON TERMINAL
BLOCK OR TRANSFORMER.
WNT165-0312-A06