• A PERFECT DRAUGHT is above all the result of a ue
that is clear of obstructions such as chokes, horizontal
sections or corners; any axial displacements should be
at a maximum angle of 45° compared to the vertical axis,
(better still if it is only 30°).
• The CHIMNEY TOP shall be the WINDPROOF type
with an inside cross section equivalent to that of the
ue and with a smoke outlet passage section at least
DOUBLE the internal one of the ue.
• To avoid draught problems, each stove should have
its own ue.
• If the stove is installed with a ue that has already
been used it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts deposited
on the inside from catching re.
• Pay particular attention to the passage of the ue
system through wooden walls or ceilings; in such cases
you should use particular certi ed elements.
6.4

CONNECTION TO FLUE PIPE

Dimensioning the ue must be executed in accordance
with EN 13384-1.
• The SMOKE connection between the stove and ue
should have the same cross section as the stove's smoke
outlet. The smoke tting must be sealed and the use of
exible metallic pipes is prohibited.
• In order to connect the stove to the chimney you may
perform maximum 3 changes of direction that should not
exceed 90°, the fume duct should not exceed 2 metres
in length and 3 metres in total (- 6.1 -).
• if the outlet is placed on the ceiling, make sure that the
rst vertical section has at least 50 cm before changing
the direction.
• Follow the indications in the technical data sheet
regarding the chimney draught value.
6.5

AIR INTAKE CONNECTION

It is necessary to provide an external air intake to
The dimensions of the hole must comply with the values
set forth in the table of technical data shown in the
"Product booklet".
• Is forbidden the intake of air for combustion from
garages, rooms where ammable materials are stored
or where there is danger of re.
• The combustion air intake should be protected by
an anti-insect grille and placed where it can not be
accidentally obstructed, and made in such a way that the
useful cross-section allows the right amount of oxygen
to reach the stove.
In the room where the stove is located, if there are one
or more extraction fans (exhaust hoods and the like),
there may be problems with combustion due to lack of
combustion air.
(-6.2-).
00 477 6020- 10/2017 - PALAZZETTI - PN - Italy