Care Recommendations

Cleaning
STAINLESS STEEL EXTERIOR
Use a nonabrasive stainless steel cleaner and apply with a
soft lint-free cloth. To bring out the natural luster, lightly
wipe the surface with a water-dampened microfiber cloth
followed by a dry polishing chamois. Always follow the
grain of stainless steel.
INTERIOR CLEANING
To clean interior surfaces and all removable parts, wash
with a mild solution of soap, water, and baking soda. Rinse
and dry thoroughly. Avoid getting water on the lights, con-
trol panel, and cherrywood facing on wine racks.
Use a standard glass cleaner to clean the UV-resistant glass
door.
CAUTION
Do not use vinegar, rubbing alcohol, or other
alcohol-based cleaners on any interior surface.
VACATIONS
For extended vacations, turn power off at the control
panel. Empty the unit and block doors open slightly to let
fresh air in and keep the interior dry.
6 | English
CONDENSER CLEANING
CAUTION
Before cleaning the condenser, turn power off to the
unit. Wear gloves to avoid injury from sharp con-
denser fins.
The condenser is located at the bottom of the unit, behind
the kickplate. Remove the kickplate by extracting the two
mounting screws. Use a soft bristle brush and vacuum to
remove dust and lint from the condenser. Clean the con-
denser every 6–12 months. Refer to the illustration below.
IMPORTANT NOTE: To avoid damaging the condenser fins,
vacuum in the direction of the fins.
CAUTION
Failure to clean the condenser could result in tem-
perature loss, mechanical failure, or damage.
CONDENSER
Condenser location

Troubleshooting

Troubleshooting
UNIT OPERATION
No lights or cooling.
Verify power is on.
Verify electrical power to the unit and home circuit
breaker is on.
No lights.
The door may have been left ajar, which has disabled
lights to eliminate excess heat. If the lights are out,
close the door for one hour. If the lights are still out,
contact Sub-Zero Factory Certified Service.
LED interior lighting must be replaced by Sub-Zero
Factory Certified Service.
Condensation forms inside the unit.
Verify the condenser is clean.
Verify the door is closing properly.
Verify the door has not been left ajar.
Verify the door gasket does not have rips or tears.
If it does, contact Sub-Zero Factory Certified Service.
High temperatures, the unit runs excessively or the unit
is giving off too much heat.
Verify the condenser is clean.
Verify the door is closing properly.
Verify the door has not been left ajar.
Increased ambient temperatures may cause the com-
pressor to run longer.
If the temperature display shows
13°C and
7°C, but is
not cooling, the unit may be in showroom mode.
Contact your authorized Sub-Zero dealer.
ODOR
The unit should be cleaned before using for the first
time. This will clear any odors that may have been
trapped during shipping.
SERVICE
Maintain the quality built into your product by contact-
ing Sub-Zero Factory Certified Service.
When contacting service, you will need the model and
serial number of your unit. Both numbers are listed on
the product rating plate. Refer to page 4 for rating plate
location.
For warranty purposes, you will also need the date
of installation and name of your authorized Sub-Zero
dealer. This information should be recorded on page 2
of this guide.

Publicidad

Tabla de contenido
loading

Tabla de contenido