Live Well Hose connection
- Connect ¾˝ I.D. hose from live well to pumps ¾˝
outlet using either the straight or 90º discharge port.
Hand tighten discharge port to pump and secure
hose with clamp. To prevent airlocks, route hose from
pump to live well with a continuous vertical rise and
no dips or loops making certain that the hose does
not drop below the pumps level.
Wash down Hose connection
– Connect ½˝ wash down hose directly to pumps
½˝ nptf hose connection. If ¾˝ hose is used connect
to pump using ½˝x ¾˝ adapter provided and either
the straight or 90º port. Secure hose with clamps.
To ensure best performance and reliability use marine
grade smooth bore hose.
Wiring the Pump
• Connect the brown wire to the positive (+) fused
side of the battery.
• Connect the black wire to the negative (-) side of
the battery.
• Install the proper size fuse; 550, 750, 950, 1250
GPH —5 Amp fuse.
• For longer pump life, do not run dry.
• Do not cut back insulation more than 3" and keep
all connections well above water levels. A submer-
ged splice will render the warranty void. Keep all
wire connections and joints high and dry. The wi-
ring connections should be made with water re-
sistant permanent terminals. Liquid electrical tape
should be used to coat the terminals.