MPPES
Warning
Use for the electrical power supply only PELV circuits in accordance with
IEC 60204-1 PELV).
Use only power sources which guarantee reliable electrical disconnection of the
operating voltage in accordance with IEC 60204-1.
Note
Check the use of the voltage or current actual signal at the MPPES-....
Use the following connection accessories (è Accessories):
– Socket with cable or
– Plug socket and screened cable
Note
Wire the following connections with earth potential:
– screening on the cable end away from the MPPES
– the functional earth connection 6 (blind hole in the aluminium housing è Fig 8)
You can then guarantee that the specified protection class IP65 and EMC are
fulfilled.
Note
Make sure that the cables are laid as follows:
–
–
–
6
Fig. 7
18
not squashed
not bent
not stretched (è Fig. 8).
Fig. 8
Festo – MPPES – 1501e English