13.5
Assembly inspection (Catalogue Chapters E12 and E16 )
13.6
Assembly safety information
Two-handed operation: hold tube – hold button down

14. Maintenance, cleaning and servicing

The power plug should always be withdrawn from its socket before any
maintenance or repair work is undertaken.

Regular maintenance

• Regular machine maintenance:
factory fitters' workshop
• Hydraulic components:
factory fitters' workshop
• Electrical circuit components:
factory electrical workshop

14.1.1 Maintenance plan

Interval
Weekly
Check oil level
Monthly
Daily
Check cables and plugs.
Daily/every 2000 c
Cleaning
les
Weekly
Cleaning
Weekly
Check wheels
Weekly
Check telescopic handle
mechanism and its safety
arrangements
Activity
Check hydraulic
system
Page
Investigate regularly for leakage, and repair
if required. (Leaks can be recognised and
located only if the machine is regularly
cleaned).
Remove the hydraulic tank clip.
The oil level should be found about 10mm
in front of the fastener.
Change defective cables and plugs.
Clean machine with a brush and cloth.
Viewing and functional inspection.
Change if required
The telescopic handle should be easily
withdrawable.
Wear on the cotter pin