EOMAT ECO
14.2 Hydraulic components
Refer to PARKER - Hydraulic 108 HDS 19-BS6-4H-33-00-Y
14.2.1 Hydraulic diagram
See appendix
14.2.2 Checking the fluid level
Check oil level regularly and replenish as required.
14.2.3 Changing the hydraulic oil
Hydraulic oil H-LP 22
Allowing this to be carried out by Parker service is recommended.
14.3
Electrical components
14.3.1 Electrical diagram
See appendix
Unscrew filler plug.
The oil level should be visible about
10mm in front of the filler plug.
The position of the bleeding plug
should be kept without fail.
It should be positioned about 35°
from the hydraulic axis, turned to the
right.
Direction of view for
the bleeding plug.