Descargar Imprimir esta página

RIB ABJ7079 Instrucciones De Montaje página 14

Ocultar thumbs Ver también para ABJ7079:

Publicidad

Idiomas disponibles

Idiomas disponibles

Pag. 14 di 20
the memory cancellation is signalled by two flashings of the DL2 green Led.
E
3 - Subsequently DL1 programming led stays active and it is possible to add new codes
N
following the procedures described above.
4 - Re-set DIP 1 - OFF and DIP 2 - OFF.
G
MEMORY SATURATION SIGNALING
L
The position of the door does not affect the code memorisation.
1 - By setting DIP 1 - ON and subsequently DIP 2 -ON.
I
2 - DL2 green Led lightens for 6 times thus signalling that the memory is full (60 codes
S
available).
3 - Subsequently the DL1 programming led stays active for 10 seconds, thus enabling the
H
possible total cancellation of the codes.
4 - Re-set DIP 1 - OFF and DIP 2 - OFF.
OPERATION OF THE OPERATING ACCESSORIES
OPERATION BUTTON (COM-K BUTTON)
If DIP6 is ON => It cyclically commands open-stop-close-stop-open-etc.
If DIP6 is OFF => It opens the door when this is closed. If it is operated while the door is
opening, it has no effect. If it is operated when the door is open, it closes
the door and, if it is operated while the door Is closing, it opens the door
again.
(automatic operation mode only DIP 6 OFF)
This function is useful In the rush hours, when vehicle traffic is slow (e.g. entry/exit of
workers, emergencies In residential or parking areas and, temporary, for removals).
APPLICATIONS
By connecting a switch and/or a daily/weekly timer (in place or in parallel with the opening
button N.O. "COM-K BUTTON"), it is possible to open the automation or to keep It open,
as long as the switch is on or the timer is activated.
When the automation is open, all operating functions are inhibited.
On switch release, or at set time, the actuator will close.
If DIP6 is ON => It cyclically commands open-stop-close-stop-open-etc.
If DIP6 is OFF => It opens the door when this is closed. If it is operated while the door is
opening, it has no effect. If it is operated when the door is open, it closes.
If it is operated while the door is closing, it opens the door again.
SAFETY ACCESSORIES OPERATION
PHOTOCELL (COM-PHOT.)
If DIP 4 is OFF - The door does not open if there is an obstacle within the photocells
range of action. During operation, photocells work both when the door
opens (by starting the opening movement again after half a second
time), and when it closes (by starting the reverse movement after one
second time).
If DIP 4 is ON - If there is an obstacle within the photocells range of action when the door
is closed and its opening is commanded, the door opens (during its
opening, photocells do not work). Photocells work only while the door is
closing (by starting its reverse motion after one second, even if they are
still engaged).
NOTE: in case this line is not used, bridge the contacts COM-PHOT.
LAMPEGGIATORE E/O LUCE DI CORTESIA
With DIP5 set ON = > it is possible to connect a flasher
N.B.: This electric board can supply power ONLY TO BLINKERS WITH (ACG7059)
BLINKING CIRCUIT, with max. 40W lamps.
With DIP5 set OFF => it is possible to connect a lamp for garage lighting (40 W max).
On every command input, the courtesy lamp will lit for 2 minutes. If during the 2 minutes
time, a second input is generated, the time elapsing will automatically restart for 2
minutes.
The pausing time before the automatic closing is set during the "Time Programming".
In this case the maximum pausing time available is 5 minutes.
Pause time can be enabled or disabled by DIP3 (ON enabled).
RESTORING OF OPERATION FOLLOWING A POWER SHUT OFF
In case of power shut off the fence stops and the control unit will keep memory of the
interrupted motion. On restoring of power a further command is necessary. Upon
command input the interrupted operation is completed (in case of opening, the open
stroke is completed...)
TIMER FUNCTION
RADIO TRANSMITTER
AUTOMATIC CLOSING
TECHNICAL DATA
Temperature range
Moisture
Power supply voltage
Frequency
Transient power mains drops
Max. power managed at the motor output
Max. load at the blinker output
Max. card power absorption (excluding the accessories) 30mA
Current available for the photocells
Protection degree
Weight of the equipment
Dimensions
TECHNICAL FEATURES OF THE RADIO (CRX MODELS ONLY)
Frequency for the reception
Impedance
Sensitivity
Energizing time
De-energizing time
Codes to be memorized
Current available on the radio connector
- All inputs shall be used as clean contacts without earthing, because the power supply is
generated in the card and is structured in such a way to guarantee the respect of double
and reinforced insulation to the elements under voltage
- All inputs are managed by a programmed circuit that carries out a self-control every time
the door is operated.
0±55°C
<95% without condensation
230V±10% (120V±10% on request)
50/60Hz
20ms
1CV
40W with resistive load
0,4A±15% 12Vdc
IP54
0,70 Kg
14,7 x 6 x 18,5cm
433,92MHz
52Ω
>2,24µV
300ms
300ms
N° 60
200mA 12Vdc

Publicidad

loading

Este manual también es adecuado para:

Abj708Abj7082Abj7081