2. Install a Y pipe in the primary sump pump discharge
pipe.
If necessary adjust the PVC pipe length so that nothing
interferes with the primary pump and switches.
4. Connect the emergency pump discharge pipe to the Y
shape pipe.
Note: Adjust the height for the emergency pump and
keep 2"-4" to the bottom.
4
3. Install a check valve in the emergency pump
discharge. Install the pipe on the check valve.
5. Install a Tee pipe in the system. One end connects to
the tap and another end connects to the emergency
pump.
Ensure that the pipe around 5" in diameter.
Use clamp to fix city water inlet pipe and discharge
pipe.