: Do not remove or
WArNING
adjust the safety valve. Keep it clean
(no dirt or paint).
Do not repair or
DANGer :
modify the deposit! Welding,
drilling or any other modification
will weaken the tank may cause a
rupture or explosion. Replace the
tank whenever is worn or damaged.
: Drain tank daily.
WArNING
12. The rust deposit as a result of
moisture accumulation. Drain the
tank and inspect regularly for signs
of rust or corrosion.
13. When draining or depressurizing
the system, slowly release the
accumulated air in the tank to avoid
raising dust.
preCAuTIoNs DurING
sprAYING
Do not spray flammable substances
near naked flames or other ignition
sources including the compressor.
14. Do not smoke while spraying
paint, insecticides or other
flammable substances.
15. Use a protective mask when
spraying. To prevent fire or health,
work only in well ventilated areas.
16. Do not contaminate the
compressor with paint or other
substance during spraying. Position
the compressor as far away
from the spray area to minimize
accumulations equipment.
17. Whenever spray or clean with
solvents or toxic chemicals, follow
the instructions provided by the
manufacturer of the substance.
18
INsTALLATIoN
LoCATIoN
It is extremely important to install
the compressor in a clean and
well ventilated where the ambient
temperature does not exceed 38
º C. There should be a minimum
distance of 50cm between the
compressor and any wall to allow
air circulation.
ATTeNTIoN: Do not place
the inlet of the compressor close
to areas of steam, sandblasting,
painting or other sources of
contamination. The particles can
damage the engine.
eLeCTrICAL
INsTALLATIoN
All the electrical
WArNING:
connections must be performed
by a qualified technician. The
installation shall be in accordance
with national regulations.
Never use an
ATTeNTIoN:
extension cord with this unit. It
is preferable to use a hose to
avoid additional power loss and
permanent damage to the engine.
The use of an extension is not
covered by warranty.
GrouND
1.This product is used in a circuit
rated at 230V. This equipment
must have a ground conductor. In
the event of a short circuit, earthing
reduces the risk of electric shock
by providing an escape line for the
electric current. This compressor
has a power cord equipped with a
ground. The plug must be inserted
into an outlet properly installed
and grounded in accordance with
national regulations.
Improper earthing may
DANGer:
result in electric shock to the user.
Do not use a ground
DANGer:
adapter with this equipment.
2. If you need to repair or replace
the power cord or plug, do not
connect the ground wire to either
terminal. The ground wire is green
(with or without yellow stripes).
Do not connect the
WArNING:
green (or green and yellow) to
another terminal.
3. If you have not fully understood
the instructions for earthing or have
doubts about the effectiveness of
the connection, consult a qualified
electrician. Do not modify the plug
provided. If you have difficulty
fitting the plug into the outlet, have
a qualified technician to install the
required outlet.
4. Electrical regulations differ from
country to country. The connection
wires, plugs and protective devices
must be sized according to the
voltage and current indicated on the
nameplate of the motor and meet
all requirements of the electrical
regulations.
5. Use a slow fuse or circuit
breaker.
Inadequate
ATTeNTIoN:
connections result in overheating,
short circuit and fire.