For Well Point Installation
Drive the well, using "drive couplings" and a "drive cap". "Drive fittings" are threaded all the way through
and allow the pipe ends to butt against each other so that the driving force of the maul is carried by the pipe
and not by the threads. The ordinary fittings found in hardware stores are not threaded all the way through
the fitting and can collapse under impact. "Drive fittings" are also smoother than standard plumbing fittings,
making ground penetration easier.
For Surface water Installation
For Professional Technical Support call 1-844-242-2475
1. Connect 1-1/4in. Drive Coupling to well point.Thread 1-
1/4in. Galv. Steel Pipe into Drive Coupling. (Fig. 1)
2. Thread 1-1/4 in. Lead Free Brass Check Valve into
Steel nipple .Install 1-1/4in.×3in. Galv. Steel Nipple into
the check valve. (For easy priming connect the check
valve as close to the well as possible). (Fig. 2)
3. Install 1-1/4in.PVC TEE FPT×FPT×FPT to the nipple.
One end of horizontal port install another 1-1/4in. PVC
MPT×S Male Adapter and 1-1/4 in. PVC rigid Pipe. Add
sections of pipes to reach the 1-1/4in. PVC Slip ×Slip
Union (optional). (Fig. 3)
1. Connect 1-1/4in.Brass Foot Valve to 1-1/4in. PVC MPT×S
Male Adapter. Cement adapter to 1-1/4 in. PVC rigid Pipe.
All connections must be air- and water-tight for pump to
operate correctly. (Fig 1)