Filter Change; Trouble Shooting; Guarantee - IP Cleaning FOX Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
4.3 Responsibility
IP Cleaning disclaims all responsibility
for all damage caused by incorrect
use or modification of the machine.

4.4 Filter change

The pre-filter (11) and post-filter (6)
can be worn and need to be replaced.
For cleaning of post-filter see 3.4
Pre-filter (11) change:
1. Turn off the vacuum cleaner
2. Remove the plug from the
wall socket
3. Remove the head from the
tank
4. Position
down
5. Remove the 4 screws fixing
the filter frame to the head
6. Remove the filter
7. Insert the new filter into the
filter frame and place it on
the head
the
head
upside
8. Fix the 4 screws. Do not over
tighten the screws.
9. Check the filter is properly
fixed and the sealing between
head and filter
secured.

5. Trouble shooting

Repair or service of electrical
components such as cord or motor,
must only be carried out by an
authorized service centre.
If the machine does not start
Check that the plug is
correctly fitted to the wall
socket.
A fuse in the building may
have blown and needs to be
changed.
The cord or plug may be
damaged
repaired by an authorized
service centre.
Reduced suction power
The tank (2) may be full
and needs to be emptied,
see instructions.
The pre-filter (11) can be
blocked and have to be
cleaned, see chapter 3.2
The bent tube, hose, tube
or nozzle may be blocked
and needs to be cleaned.

6. Guarantee

This vacuum cleaner is covered by a
two
(2) year guarantee on the
22
EN
frame
and
must
be
is

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido