Cleaning
For cleaning purposes, the fitting can be switched off by
attaching the enclosed cleaning clip (K), see Fig. [8].
Maintenance
Shut off cold and hot water supplies.
Inspect and clean all components and replace if necessary.
I. Battery
Batteries which are almost discharged are indicated by
a flashing indicator lamp.
1. Fit cleaning clip (K), see Fig. [9].
2. Unscrew and remove screw (L) and remove housing (M).
3. Pull off protective sleeve (N) and take out battery (O), check
contacts, clean and if necessary replace.
Assemble in reverse order.
II. Solenoid valve
1. Proceed as for maintenance of battery, points 1 to 3.
2. Unscrew and remove screws (P1) and pull out battery
tray (P), see Fig. [10].
3a.Detach plug-in connector (R) and remove solenoid
valve (S) by turning clockwise (left-hand thread) using
a 5mm allen key, see Fig. [11].
3b.Detach plug-in (R) connector and pull out solenoid
valve (S).
4. Remove filter (T).
Install in the reverse order, note installation position.
Fault/ cause/ remedy
Fault
Water not flowing
Indicator lamp
flashing
Water flowing
continuously
Undesired/
excessively long
Flow rate too low
Mixing device
incorrect
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
Cause
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve without
contact
• Battery discharged
• Battery almost discharged
• Solenoid valve defective
• Detection range of sensor system set too
high for local conditions
• Erroneous activation due to object within
detection range of sensor system
• Filters or mousseur dirty
• Service valves not fully open
• Water supply restricted
• See "Flow rate too low"
• Limescale on mixer spindle
• Temperature limiter incorrectly set
III. filter
1a. Unscrew connection hose, detach adaptor (C) with
integrated non-return valve and remove filter (B), see
Fig. [12].
1b. Unscrew connection hose and remove filter (B), see
Fig. [13].
Assemble in reverse order.
IV. Remove and clean mousseur (42 832).
Assemble in reverse order.
V. Mixer spindle
1. Disconnect fitting from connections.
2. Remove fitting from wash basin.
Disassembly is as described in section Setting temperature
limiter, see Figs. [5] and [7].
3. Remove screw (U) from housing using a 2.5mm allen key.
4. Pull out mixer spindle (G, J), see Fig. [14].
Assemble in reverse order.
Screw (U) must engage in groove (G1, J1) of mixer
spindle (G, J).

Replacement parts

see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.

Disposal note

Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves, service valves
- Clean, see Solenoid valve maintenance
- Replace, see Solenoid valve maintenance
- Attach plug-in connector
- Replace, see Battery maintenance
- Replace, see Battery maintenance
- Replace, see Solenoid valve maintenance
- Reduce range using remote control (special
accessory, Prod. no.: 36 206)
- Install base (special accessories,
Prod. no.: 36 210)
- Replace, see Filter and mousseur maintenance
- Fully open shut-off valves, service valves
- Check supply lines, open service valves
- Clean, see Mixer spindle maintenance
- Setting, see Setting temperature limiter