Kohler K-1913 Guia De Instalacion página 13

Ocultar thumbs Ver también para K-1913:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Remove the Door (cont.)
IMPORTANT! Cover the receptor tray with protective material to avoid damaging it.
Raise and latch the door.
Have the second installer hold the door up and brace it using a 2x4 under the door, with the bottom
end of the 2x4 positioned on the subfloor (not the receptor tray).
CAUTION: Risk of personal injury. When the screw is removed from the roller assembly plate,
friction is the only force holding the roller assembly in place. To avoid injury or damage to the
bath, make sure the roller assembly does not fall.
On the side of the door opposite the drain and fill spout, carefully remove the screw nearest the
rubber door stop securing the cover plate and roller assembly on the bottom of the door. Take care
not to strip the screw heads.
Slide the roller assembly down 2" (51 mm) to 4" (102 mm). If it sticks, gently pry or tap the roller
assembly from above to help lower it.
Unplug the power cord from the inside of the door by reaching up into the recess that the plate
covered.
Remove the power cord from the door, then slide the roller assembly all the way down, leaving it
intact. Further disassembly of the cord from the roller assembly is possible but typically not needed.
IMPORTANT! Do not cut the cable ties securing the power cord to the roller assembly.
NOTE: The power cord is held in place by a bracket at the base of the roller assembly. Do not remove the
bracket unless necessary.
Rest the roller assembly on the receptor tray with the power cord attached.
Remove the 2x4 while supporting the door.
NOTE: The roller assembly on the drain side of the door will remain attached.
Squeeze the door handle and pivot the door out of the track on the side opposite the drain.
Remove the door and carefully set it aside.
Kohler Co.
13
1128532-2-H

Publicidad

Tabla de contenido
loading

Tabla de contenido